Steam Electrical Generator Trainer
The Steam Power Generation / Thermodynamics Trainer is purpose-designed and built for hands-on education and training on topics related to steam generation, power generation, and control. This Trainer demonstrates the conversion of stored chemical energy to electricity; the primary method of generating electricity used today. The trainer uses a natural gas boiler to generate steam which is then expanded in a steam turbine, converting the heat energy of the steam into electrical energy via the turbo-generator.
This steam electrical generator unit is mounted completely on a single skid (except for the remotely installed resistive load bank), allowing for compact installation. Industrial-type process components, process measurement, and control devices have been used throughout the training to provide the student with a realistic training experience using equipment common to the industry. This trainer is a real system that generates electricity from a natural gas fuel on a small scale. In every other respect, the system is designed, operated, controlled, and maintained in the same way as the full-scale industrial electrical generating facilities.
Two Available Options:
- Complete electrical power generation unit
- Electrical Power Generation unit with enhancements for combustion analysis and overall system efficiency. Fuel flow, air flow, steam mass flow, and flue-gas analyzer plus connection to and configuration of DCS to display process variables.
System Capacity:
- The nominal electrical output of up to 12 kW 208 VAC 3-phase
Intended Training Topics:
- Pressure boilers
- Steam turbine/alternators and controls
- Thermodynamics
- Power System Operation and Control
Sub Topics:
- Boiler operation and controls
- Turbine/alternator operation
- Alternator and power switching controls
- Combustion reaction stoichiometry
- Efficiency calculations
Equipment Specification Highlights:
- Boiler
- (25 Hp nominal) Natural gas (liquid fuel options available), 863 lbs of saturated steam at 150 psi
- Full automatic control via integrated PLC and communication with DCS
- Turbine
- Single stage, integrated speed governor and over-speed trip device
- Centrifugal-type condensate return and boiler-feed water pumps
- Electrical generation equipment
- Alternator developing up to 10-15 kW 3-phase electrical power (voltage and frequency determined by installation country)
- The power dissipated in a resistive load bank with variable load controls – variable in 14 steps up to 15 kW
- Integrated switchgear and safety controls (synchronize power to the grid like a real power system)
- All industrial indications and controls
- Optional Analytical controls
- Combustion reaction reactant and product flow measurement and gas analysis equipment
- Fuel and air flow meters
- Steam flow mete
- Flue gas analyser (O2, CO2, and CO)
- Operator controls
- Emerson DeltaV distributed control system that operates in parallel to the local control systems provided as integrated with the parts steam system components. The DCS will provide overall alarming and control functions in parallel and cooperation with the local control systems integrated with the steam components.
- Skid Approximate Dimensions; custom dimensions available to fit available space
- 2.3 x 5.5 x 3.0 m high, allowing for access to the equipment for teaching purposes as well as the ability to insulate the system to prevent excessive heat loss.
Codes and Standards:
- Steam system components comply with or exceed sound engineering practices and all standards and codes applicable to operation at the installation site, including but not limited to the relevant ASTM and ASME. Components will be marked with the applicable designations.
- Electrical components shall comply with or exceed CSA and/or UL standards and approvals. Components are marked with the applicable designations.
- Engineering Standards. The design and fabrication shall conform to normal industry practices
Control Component Protocol:
- Hart 4-20 mA standard
Utility Supply Requirements:
- 120 VAC, 60 Hz single-phase power (240 VAC, 50 Hz available)
- 440 VAC 60 Hz three-phase power (415 VAC 50 Hz available)
- Clean, Dry instrument air to 35 psig minimum
- Natural gas supply
- Cooling Water Supply
- Draft air supply
- Appropriate flue gas exhausts
Contact DarbyTech
For detailed technical information about specific DarbyTech Training Equipment, including pricing for budgeting purposes or a quotation, please complete and submit this information: